home *** CD-ROM | disk | FTP | other *** search
/ Power Tools 1993 November - Disc 1 / Power Tools Plus (Disc 1 of 2)(November 1993)(HP).iso / 3khw / 50914064 / sec02 / sec02.txt < prev    next >
Text File  |  1992-08-25  |  44KB  |  1,203 lines

  1.  
  2.  
  3.  
  4.  
  5.  
  6. Series 9x7LX and 9x7 Systems
  7. 92/29/06
  8.  
  9. General System Configuration Information
  10.  
  11.  
  12. Maximum Supported Hardware Configuration
  13. ∅ || 917LX || 927LX || 937LX || 937 || 947LX || 947 || 957LX ||
  14. 957 || 967LX || 967 || 977 || 987
  15. =MPE/iX Release Support  3.1/4.0
  16. =User license: (UL=unlimited)- standard - optional ||
  17. 8||
  18. 20||
  19. 32 40/64 ||
  20. 32 40/64 ||
  21. 100UL ||
  22. 100UL ||
  23. 64  100/UL ||
  24. 64  100/UL ||
  25. 100  160/UL ||
  26. 100  160/UL ||
  27. 100  160/UL ||
  28. 100  160/UL
  29. =Typical users  || 8 || 16 || 24 || 24 || 48 || 64-100 || 64-100 || 64-160 ||
  30. 64-100 || 96-250 || 96-300 || 96-380
  31. =Maximum connected workstations || 64 || 64 || 152 || 152 || 410 || 410 || 655
  32. || 655 || 655 || 850 || 1050 || 1300
  33. =Performance relative to 917LX || 1.0 || 1.0 || 1.0 || 1.0 || 1.0 || 1.0 || 1.6
  34. || 1.6 || 2.0 || 2.0 || 2.6 || 3.2
  35. =HP-PB Slots || 2 || 2 || 2 || 12 || 2 || 12 || 2 || 12 || 2 || 12 || 12 || 12
  36. =Memory (MB): Standard/Maximum || 24/192 || 24/192 || 32/192 || 32/384 ||
  37. 48/192 || 64/384 || 64/192 || 64/384 || 64/192 || 64/512^^5^^ || 96/768^^5^^ ||
  38. 96/768^^5^^
  39. =Maximum disk storage (GB)|| 24 || 24 || 24 || 66 || 24 || 66 || 24 || 66 ||
  40. 24 || 66 || 66 || 66
  41. =Maximum disks: Total - HP-FL - SCSI - HP-IB^^4^^ ||
  42. 18  8  18  6 ||
  43. 18  8  18  6 ||
  44. 18  8  18  6 ||
  45. 49  24  25  12 ||
  46. 18  8  18  6 ||
  47. 49  24  25  12 ||
  48. 18  8  18  6 ||
  49. 49  24  25  12 ||
  50. 18  8  18  6 ||
  51. 49  24  25  12 ||
  52. 49  24  25  12 ||
  53. 49  24  25  12
  54. =Maximum tape drives || 6 || 6 || 6 || 8 || 6 || 8 || 6 || 8 || 6 || 8 || 8 ||
  55. 8
  56. =Maximum printers  - system  - serial||
  57.  6  32 ||
  58.  6  32 ||
  59.  6  32 ||
  60.  8  48 ||
  61.  6  32 ||
  62.  8  48 ||
  63.  6  32 ||
  64.  8  64 ||
  65.  6  32 ||
  66.  8  64 ||
  67.  8  64 ||
  68.  8  64
  69. =Maximum DTCs || 4 || 4 || 6 || 6 || 12 || 12 || 24 || 24 || 24 || 24 || 24 ||
  70. 24
  71. =Max. # devices per I/O card  - SCSI  - PBA-IB (HP-IB)^^4^^
  72.  - PB-FL (HP-FL) 28616A  - PBA-FL (HP-FL) A1748A ||
  73.  7  6  8  8 ||
  74.  7  6  8  8 ||
  75.  7  6  8  8 ||
  76.  7  6  8  8 ||
  77.  7  6  8  8 ||
  78.  7  6  8  8 ||
  79.  7  6  8  8 ||
  80.  7  6  8  8 ||
  81.  7  6  8  8 ||
  82.  7  6  8  8 ||
  83.  7  6  8  8 ||
  84.  7  6  8  8
  85. =Maximum number of cards  - PBA-IB cards^^4^^  - PB-FL
  86. cards (28616A)  - SCSI cards  - PBA-FL (A1748A)  -
  87. Maximum combined PB/PBAs ||
  88.  1  1  2  0  1 ||
  89.  1  1  2  0  1 ||
  90.  1  1  2  0  1 ||
  91.  2  3  10 3  3 ||
  92.  1  1  2  0  1 ||
  93.  2  3  10 3  3 ||
  94.  1  1  2  0  1 ||
  95.  2  3  10 3  3 ||
  96.  1  1  2  0  1 ||
  97.  2  3  10 3  3 ||
  98.  2  3  10 3  3 ||
  99.  2  3  10 3  3
  100. =Max. network links per system  - 802.3 LANIC2
  101.  - 802.5 Token Ring ||
  102.  2  1 ||
  103.  2  1 ||
  104.  2  1 ||
  105.  2  1 ||
  106.  2  1 ||
  107.  2  1 ||
  108.  2  1 ||
  109.  2  1 ||
  110.  2  1 ||
  111.  2  1 ||
  112.  2  1 ||
  113.  2  1
  114. =Floating point coprocessor || N/A || N/A || opt || opt || opt || opt ||
  115. opt || opt || opt || opt || opt || std
  116. =Maximum PSI cards || 2 || 2 || 2 || 5^^6^^ || 2 || 5^^6^^ || 2 || 5^^6^^ || 2
  117. || 5^^6^^ || 5^^6^^ || 5^^6^^
  118. =Supplied Manual Set^^3^^||9x7LX Core || 9x7LX Core || 9x7LX Core || Sys Mgmt
  119. Core || 9x7LX Core || Sys Mgmt Core ||9x7LX Core || Sys Mgmt Core & Core Plus
  120. ||9x7LX Core  Sys Mgmt Core & Core Plus
  121.  
  122. 1Add-on cards, does not include integrated SCSI interface
  123.  
  124. 2First card standard on multi-function I/O card
  125.  
  126. ^^3^^See Chapter 8 for description of manual sets
  127. ^^4^^Six disks are physically supported per PBA-IB.
  128. Four disks per PBA-IB are recommended for optimum
  129. performance.
  130. ^^5^^Effective with MPE/iX Release 4.5
  131. ^^6^^If three PBA-FL cards (A1784A) are installed, maximum PSI cards are four
  132.  
  133.  
  134. Unique Supplied Hardware
  135.  
  136.  
  137. * One Multi-Function I/O card (MFIO) containing 802.3 LANIC, two RS-232 C ports
  138. (for
  139. console and remote support connections), SCSI interface, integrated ThinLAN
  140. Transceiver, and AUI connector
  141. * One 2 meter ThinLAN cable and a pair of ThinLAN terminators
  142. * Integrated SCSI disk drive: 673 MB (917LX), 1355 MB (927LX, 937LX, 937,
  143. 947LX, 947, 957LX, 957, 967LX, 967, 977, 987)
  144. * Integrated SCSI DDS format tape drive with 2.0 Gbytes capacity per cassette,
  145. 1 DDS cleaning cassette, 1 blank DDS cassette
  146. * One 700/92 terminal (console) and cable
  147.  
  148.  
  149. Unique Supplied Software
  150.  
  151.  
  152. * HP Easytime/XL system management interface (Series 9x7LX only)
  153.  
  154.  
  155. Packaging
  156.  
  157. The Series 9x7LX and 9x7 systems are offered in two different package types:
  158.  
  159.  
  160. * The Series 9x7LX package is a small,
  161. integrated deskside package offering two I/O expansion slots, space for one 3
  162. 1/2-inch DDS format tape drive, and one internal 5 1/4-inch disk mechanism.
  163. *The Series 9x7 package is a larger deskside package
  164. offering twelve I/O expansion slots and space for one internal 3 1/2-inch DDS
  165. format tape drive, and up to three 5 1/4-inch disk mechanisms.
  166.  
  167.  
  168. Upgrades from the small package to the large package are available. Also, both
  169. packages are rack mountable in a 1.1 or 1.6 meter cabinet (P/Ns A1883A,
  170. A1884A). Option 1CM under the system product number provides the necessary
  171. hardware to rack mount the systems in a 1.1 meter or 1.6 meter cabinet.
  172. %%See page 2-8 to 2-12 for more information on cabinet solutions.%%
  173.  
  174. Memory Expansion
  175.  
  176. Error correcting memory is supplied with each SPU. Additional memory can be
  177. obtained by ordering options 503-519 with the system, or by ordering the
  178. stand-alone products: A2230A (8 Mbytes), A2231A (16 Mbytes), A2232A (32
  179. Mbytes), A2511A (64 Mbytes), or A2516A (128 Mbytes).
  180.  
  181. Memory consists of memory modules of 4, 8, 16, 32, and 64 Mbytes which must be
  182. installed in pairs of identical size. Add-on memory products consist of an
  183. identical pair of memory modules. For example, the 32 Mbyte add-on memory
  184. product (A2232A) contains two 16 Mbyte modules.
  185.  
  186. The systems have the capacity to support a total combination of six pairs of
  187. memory modules.  On all 9x7LX systems, maximum memory of 192 Mbytes can be
  188. achieved through
  189. the use of six pairs of 16 Mbyte memory modules. For 9x7 systems, maximum
  190. memory of 384 Mbytes is provided by six pairs of 32 Mbyte memory modules.
  191. Adding
  192. memory in smaller increments will reduce the maximum amount of memory possible.
  193.  
  194.  
  195. Maximum memory on the Series 967 is 512 Mbytes, and on the Series 977
  196. and 987 is 768 Mbytes, effective with MPE/iX Release 4.5.
  197.  
  198.  
  199. Memory modules are installed on the private memory bus and do not use HP
  200. Precision Bus expansion slots.
  201.  
  202. Floating Point Coprocessor
  203.  
  204. An IEEE floating point coprocessor is available as an option (8Z7) to Series
  205. 937LX, 937, 947LX, 947, 957LX, 957, 967LX, 967, and 977 systems for high
  206. performance in numerical
  207. applications. The coprocessor is built into the SPU so no installation is
  208. required. Floating point is standard on the Series 987 by combining the CPU and
  209. floating point coprocessor onto one chip.
  210.  
  211. Due to the tremendous performance of the 917LX and 927LX, a separate floating
  212. point coprocessor is not deemed necessary.
  213. Floating point operations for these systems
  214. are adequately handled via the system processor and high speed system software
  215. routines.
  216.  
  217.  
  218. Several HP 3000 third party applications and tools require the floating point
  219. coprocessor for optimal performance. Consult your third party software supplier
  220. for the floating point requirements of their specific application.
  221.  
  222.  
  223. HP EasyTime/XL
  224.  
  225. HP EasyTime/XL is an easy-to-use interface for commonly performed system
  226. management functions on Series 9x7LX systems. HP EasyTime/XL must be ordered
  227. separately.  Part number B1940A will preload HP EasyTime/XL on the system disk
  228. at the factory and provide future updates on Series 9x7LX systems.
  229.  
  230. Based upon an easy-to-use user interface, HP EasyTime/XL provides novice system
  231. managers and end users with limited computer experience access to commonly used
  232. system management utilities while shielding the user from the complexity of
  233. MPE/iX.
  234.  
  235. Factory Software Pre-loading
  236.  
  237. Factory pre-loading of HP 3000 FOS and standard subsystem software is available
  238. with HP 3000 9x7LX and 9x7 systems.  This software will be factory installed on
  239. the standard integrated disk provided with each system.  In order to have all
  240. HP subsystem software pre-installed at the factory, order MPE/iX media product
  241. (51453A option 0D1) on the same order section as the system and specify a
  242. coordinated shipment.
  243.  
  244. User Licenses
  245.  
  246. All Series 9x7LX and 9x7 systems are supplied with a software class/concurrent
  247. license specifying the maximum number of users. Some systems are
  248. available with options to increase the maximum number of users. The practical
  249. number of concurrent users is dependent on the application mix and response
  250. time/throughput requirements.
  251.  
  252.  
  253.  
  254. I/O Channel Configuration Information
  255.  
  256. HP Precision Bus (HP-PB)
  257.  
  258. HP 3000 Series 9x7LX and 9x7 systems connect to peripheral devices and data
  259. communication networks via the HP Precision Bus (HP-PB).  In compliance with
  260. the Eurocard standard, the HP Precision Bus supports both single-high and
  261. double-high I/O cards.  Single-high I/O cards use one Precision Bus slot each
  262. and double-high I/O cards use two slots each. Single-high Precision Bus cards
  263. include SCSI, PSI, second 802.3 LANIC, and 802.5 Token Ring cards.  Double-high
  264. Precision Bus cards include PBA-IB and
  265. PBA-FL interfaces.  The table below illustrates the slot usage for the various
  266. adapter cards supported on the Series 9x7LX and 9x7 systems.
  267.  
  268.  
  269. Adapter Card         || Size         || HP-PB slots\used per card
  270.  
  271. =SCSI                ||  Single-high || 1
  272. =802.3 LANIC         || Single-high  || 1
  273. =802.5 Token Ring    || Single-high  || 1
  274. =PSI                 ||  Single-high || 1
  275. =PBA-IB (HP-IB)      || Double-high  || 2
  276. =PBA-FL (HP-FL)^^1^^ || Double-high  || 2
  277. =PB-FL (HP-FL)^^2^^  || Double-high  || 2
  278.  
  279.  
  280. ^^1^^The PBA-FL card is supported on Release 3.1 and 4.0.  PB-FL
  281. replaces the PBA-FL.
  282. ^^2^^The PB-FL card is supported on Release 4.0
  283. and later 
  284.  
  285. The Series 9x7LX systems support up to two SCSI or PSI cards, one PBA-IB card,
  286. or one PB-FL card (28616A). The Series 9x7 systems support up to twelve
  287. single-high cards (such as SCSI or PSI), or two double-high PBA-IB cards, or
  288. three double-high cards (PBA-FL, PB-FL) or a combination thereof.
  289.  
  290.  
  291. Series 9x7LX System Layout
  292.  
  293.  
  294. Series 9x7 System Layout
  295.  
  296.  
  297. Installing double-high cards will impact the number of available single wide
  298. slots available for single-high cards. Use the table below to determine
  299. slot availability.
  300.  
  301.  
  302.  
  303. System || HP-PB Slots\Available || Double-High\Cards Used ||HP-PB Slots\Remaining
  304.  Series 9x7LX || 2              || 0                      || 2
  305. =∅      ||                || 1                      || 0
  306.  
  307. Series 9x7    || 12             || 0                      || 12
  308. =             ||                || 1                      || 10
  309. =             ||                || 2                      || 8
  310. =             ||                || 3                      || 6
  311.  
  312.  
  313. For example, if a customer has one HP-IB printer or HP-IB back-up device on a
  314. Series 9x7LX system, no HP-PB slot remains.  Consequently, a Series 9x7 package
  315. with its expanded I/O slots may need to be purchased.
  316.  
  317.  
  318. I/O Block Diagram
  319.  
  320.  
  321. Multi-Function I/O Card  (MFIO)
  322.  
  323. One MFIO card is supplied standard with each Series 9x7LX and 9x7 system. This
  324. card provides:
  325.  
  326. *802.3 LAN connection for use with both DTC and system-to-system LAN traffic
  327. (integrated ThinLAN Transceiver and AUI connector)
  328. *two RS-232-C ports for console and remote support connections
  329. *one SCSI interface which provides connection for five SCSI devices
  330.  
  331.  
  332.  
  333. The MFIO card does not utilize any Precision Bus slots.
  334.  
  335. External 2.0 GB DDS tape drives are supported on the integrated SCSI interface,
  336. but 1.3 GB DDS drives are not.  An add-on SCSI interface card is required to
  337. support external 1.3 GB DDS tape drives.
  338.  
  339.  
  340. Precision Bus Adapter (PBA)
  341.  
  342. The Precision Bus Adapter (PBA) is supported in the Series 9x7LX and 9x7
  343. systems to provide connectivity to CIB HP-IB. The Precision Bus Adapter
  344. (PBA) is supported on the Series 9x7 systems to provide connectivity to CIB
  345. HP-FL.  The
  346. PBA combines the functionality of a CIB adapter and physical bus adapter into a
  347. single card.  Only one CIB HP-IB or CIB HP-FL can be connected to each PBA.
  348.  
  349. The Series 9x7LX systems support one PBA-IB (PBA with HP-IB) while
  350. the Series 9x7 systems support a maximum of two PBAs.
  351. %%Consult page 2-1 for PBA-IB maximums.%%
  352.  
  353. The Series 9x7LX systems support zero PBA-FLs, while the Series 9x7 systems
  354. support a maximum of three PBAs.  The PB-FL (28616A) replaces the PBA-FL
  355. (A1748A).
  356.  
  357. Integrated Peripherals
  358.  
  359. The Series 9x7LX systems come standard with and support two embedded SCSI
  360. peripherals:
  361.  
  362. *one DDS format tape drive
  363. *one 5 1/4-inch disk mechanism (673 Mbyte or 1.3 Gbyte capacity)
  364.  
  365.  
  366. For additional disk storage or tape backup, external peripherals are required.
  367.  
  368. The Series 9x7 systems come standard with two embedded SCSI peripherals:
  369.  
  370. *one DDS format tape drive
  371. *one 1.3 Gbyte capacity 5 1/4-inch disk mechanism
  372.  
  373. Up to two additional 1.3 Gbyte SCSI disk mechanisms are supported inside the
  374. package, providing up to 4 Gbytes of internal disk storage.
  375.  
  376. %%Refer to pages 2-4 and 2-5 for a diagram of the system layout.%%
  377.  
  378.  
  379. C2463 (5 1/4-inch SCSI DDS) is ONLY supported on the Series 9x7LX and 9x7
  380. systems.  It is NOT supported on other platforms.
  381.  
  382.  
  383. Customer Installability
  384.  
  385. Everything the customer needs for easy SPU installation is included on the
  386. Series 917LX, 927LX, and 937LX systems.  Installation by the HP Customer
  387. Engineer is available
  388. at an extra cost for these systems.  The remaining 9x7LX systems and all Series
  389. 9x7 systems include CE installation.
  390.  
  391. Many add-on products to Series 9x7LX systems will include HP CE installation.
  392. Some of the most common are networking products, additional I/O products,
  393. DTC48s (2345A), and large disk configurations.  Customers purchasing Series
  394. 9x7LX systems with these CE installable products are expected to perform the
  395. routine system set-up and complete minimum site preparation activities prior to
  396. HP CE arrival. Cabinets with systems and peripherals racked at the factory
  397. include HP CE installation.
  398.  
  399. All Series 9x7LX systems come from the factory with CPU, memory, base I/O, and
  400. integrated mass storage devices.  In addition, the MPE/iX operating system and
  401. HP subsystem software comes pre-installed on the internal disk.  Special
  402. easy-to-understand learning products are shipped with the system to assist the
  403. novice customer through the initial startup.
  404.  
  405. The 917LX, 927LX, and 937LX systems are customer-installable if the
  406. configuration is limited to the following:
  407.  
  408.  
  409. * SPU and memory
  410. * Multi-Function I/O card (LAN/Console connection/SCSI)
  411. * system console
  412. * DTC16 (option 0DG &endash; 6 modem/8 direct connect ports, ThinLAN)
  413.  
  414.  
  415. The SPU, memory, and base I/O come preinstalled at the factory.
  416. Default configurations for up to three 14 port (6 modem/8 direct) DTC16s are
  417. preloaded on the system at the factory as well.  Customers are expected to
  418. connect the system console and DTC16 only.
  419.  
  420. Many peripherals are customer installable.  Some of the most common are:
  421.  
  422.  
  423. * additional workstations
  424. * RS-232 printers
  425. * external peripheral package (up to 1 Series 6000 multi-mechanism package)
  426. * additional DTC16s (up to 3 total in 14 port configurations)
  427.  
  428.  
  429. While not included in the system price, installation and site services can be
  430. purchased for these "customer installable" components from HP's Professional
  431. Services and Systems Support organizations. Since larger
  432. configurations increase the installation time and complexity, there is a limit
  433. to customer installable configurations.  The limits are one external peripheral
  434. package only and up to three DTC16s.
  435.  
  436.  
  437.  
  438. Many peripherals, networking, and I/O include HP CE installation.  They are:
  439.  
  440.  
  441. * HP-IB interfaces/devices
  442. * PB-FL interfaces/devices
  443. * additional SCSI interfaces
  444. * 802.3 LAN
  445. * 802.5 Token Ring
  446. * Remote communication products based on PSI
  447. * X.25
  448. * DTC16 in configurations other than 14 ports (6 remote, 8 local)
  449. * DTC48
  450. * add-on memory not ordered as an option to the system
  451.  
  452.  
  453.  
  454. In Europe, HP CE installation is bundled into the system price for all Series
  455. 9x7LX and 9x7 systems.
  456.  
  457.  
  458.  
  459.  
  460. Cabinets
  461.  
  462. Product Overview
  463.  
  464. Two cabinets are available for racking HP 3000 Series 9x7LX and 9x7 systems
  465. as well as associated peripherals and DTCs. Both a 1.1 meter cabinet, providing
  466. 21 EIA units (1 EIA unit = 1.75 in.) of usable rack height, and a 1.6 meter
  467. cabinet, with 32 EIA units of rack space, are available.
  468.  
  469. How to Order Cabinets and Peripherals
  470.  
  471. Cabinets may be ordered as a total integrated
  472. solution assembled at the factory or as stand-alone products where the system
  473. and peripherals are rack mounted in the cabinet at the customer site.
  474. The cabinets support a variety of combinations of HP 3000 systems, disk drives,
  475. tape drives, and DTCs. Combinations of supported products are limited only by
  476. space inside the cabinet.
  477.  
  478. Cabinet Overview
  479.  
  480.  
  481. Product\Number || Factory\Integrated || Racking Space\Available\(EIA
  482. units)|| Power\Distribution ||Maximum Current || Height || Width || Depth
  483.  
  484. =C2785A || No   || 21 || 100-120V/200-240V || 16A || 1.1 m  || .48 m ||  .9 m
  485. =A1883A || Yes  || 21 || 100-120V/200-240V || 16A || 1.1 m  || .48 m ||  .9 m
  486. =C2786A || No   || 32 || 200-240V          || 16A || 1.6 m  || .48 m ||  .9 m
  487. =A1884A || Yes  || 32 || 200-240V          || 16A || 1.6 m  || .48 m ||  .9 m
  488.  
  489.  
  490. Supported Racked Components
  491.  
  492. The Series 9x7LX and 9x7 cabinets support a variety of HP 3000 9x7LX and 9x7
  493. SPUs, disk drives, tape drives, and DTCs.  Combinations of supported products
  494. are limited only by space inside the cabinet and the 16-amp maximum limit.
  495. Factory Integrated Cabinets have been structured so that all orderable
  496. configurations will not exceed the 16-amp maximum current limit.  When
  497. configuring cabinets to be installed in the field, the configuration should be
  498. checked to ensure it does not exceed the 16-amp maximum current limit.
  499.  
  500.  
  501. Components Supported in the 1.1 and 1.6 Meter Cabinets
  502.  
  503. Product Number  Description  EIA
  504. Units  Required Mounting Hardware Current
  505. Consumption
  506.  
  507. =&empty ||  ||  ||  || 120 VAC || 208 - 240 VAC
  508.  
  509. ++SPUs++
  510.  
  511. =A1770A || Series 917LX || 6 || C2797A for standalone rack  Option 1CM
  512. for factory installed rack || 6.5 A || 3.5 A
  513. =A1771B || Series 927LX || 6 || C2797A for standalone rack
  514.  Option 1CM for factory installed rack || 6.5 A || 3.5 A
  515. =A1758A || Series 937LX || 6 || C2797A for standalone rack
  516.  Option 1CM for factory installed rack || 6.5 A || 3.5 A
  517. =A1772A || Series 937 || 10 || C2798A for standalone rack
  518.  Option 1CM for factory installed rack || 12 A || 6 A
  519. =A1752A || Series 947LX || 6 || C2797A for standalone rack
  520.  Option 1CM for factory installed rack || 6.5 A || 3.5 A
  521. =A1708A || Series 947 || 10 || C2798A for standalone rack
  522.  Option 1CM for factory installed rack || 12 A || 6 A
  523. =A1707A || Series 957LX || 6 || C2797A for standalone rack
  524.  Option 1CM for fctory installed rack || 6.5 A || 3.5 A
  525. =A1709A || Series 957 || 10 || C2798A for standalone rack
  526.  Option 1CM for factory installed rack || 12 A || 6 A
  527. =A1757A || Series 967LX || 6 || C2797A for standalone rack
  528.  Option 1CM for factory installed rack || 6.5 A || 3.5 A
  529. =A1710A || Series 967 || 10 || C2798A for standalone rack
  530.  Option 1CM for factory installed rack || 12 A || 6 A
  531. =A2300A || Series 977 || 10 || C2798A for standalone rack
  532.  Option 1CM for factory installed rack || 12 A || 6 A
  533. =A2317A || Series 987 || 10 || C2798A for standalone rack
  534.  Option 1CM for factory installed rack || 12 A || 6 A
  535.  
  536.  
  537. ++Continued on next page.++
  538.  
  539.  
  540. Components Supported in the 1.1 and 1.6 Meter Cabinets (cont.)
  541.  
  542. Product Number  Description  EIA
  543. Units  Required Mounting Hardware Current
  544. Consumption
  545.  
  546. =&empty ||  ||  ||  || 120 VAC || 208 - 240 VAC
  547.  
  548. ++Tape Drives^^1^^++
  549.  
  550. =7979A || 1/2-inch tape drive || 5 || opt. 1A4 and three C2790A ballasts|| 2.81
  551. A || 1.46 A
  552. =7980A || 1/2-inch tape drive || 5 || opt. 1A4 and three C2790A ballasts ||
  553. 2.81
  554. A || 1.46 A
  555. =7980XC || 1/2-inch tape drive || 5 || opt. 1A4 and three C2790A ballasts||
  556. 2.81 A || 1.46A
  557.  
  558. ++Series 6000 SCSI Multi-Mechanism Package++ (also
  559. available as integrated cabinet option)
  560.  
  561. =C2462R || 1.3 GB disk       || 4 || Included || 2.6 A || 1.5 A
  562. =C2464R || 2 GB DDS          || 4 || Included || 2.6 A || 1.5 A
  563. =C2465R || Two SCSI 2 GB DDS || 4 || Included || 2.6 A || 1.5 A
  564.  
  565. ++HP-FL Disk Array^^2^^++
  566.  
  567. =C2252HA || 2.72 GB high availability disk array || 6 || Included || 4.0 A ||2.0 A
  568. =C2254HA || 5.44 GB high availability disk array || 6 || Included || 4.0 A ||2.0 A
  569. =C2252B  || 2.72 GB disk array with 2 disks      || 6 || Included || 4.0 A || 2.0 A
  570. =C2254B  || 5.44 GB disk array with 4 disks      || 6 || Included || 4.0 A || 2.0 A
  571.  
  572. ++Data Terminal Connects++
  573.  
  574. =2340A || DTC16 || 6 || 35199E || 2 A || 1 A
  575. =2345A || DTC48 || 6 || C2799A || 2 A || 1 A
  576.  
  577. ++Filler Panels++
  578.  
  579. 40101A/2A/3A/4A/5A/6A/7A - 1 to 7 filler panels
  580.  
  581.  
  582. ^^1^^Three anti-tip ballasts (C2790A) are required for one or more 1/2-inch
  583. tape drive mechanism.
  584. ^^2^^If HP-FL disk is the bottom-most racked deviced in the cabinet, add two
  585. EIA space units.  This will allow ample space for cables coming into the bottom
  586. of the cabinet.%%
  587.  
  588.  
  589.  
  590.  
  591. Integrated System Solution (A1883A and A1884A)
  592.  
  593. To ease ordering and speed installation, integrated cabinet products are
  594. the preferred choice for customers desiring a racked system solution. These
  595. products contain options for disk storage, DTCs, and a DDS tape drive. When
  596. the system and racking options are ordered together, the
  597. entire system (including SPU, disk, tape, and DTC) will be
  598. pre-installed in the cabinet prior to shipment from the factory.
  599.  
  600. Customers desiring to have peripheral only configurations (DTC48, disk, DDS)
  601. can use these products to meet their racking needs as well. Add-on DTC48,
  602. Series 6000 multi-mechanism products (disk and DDS), and 7980/7980XC tape
  603. drives not in the Integrated Cabinet product structure will need to be
  604. installed at the customer site. %%Refer to table on page 2-11 for the necessary
  605. hardware to rack these components.%%
  606.  
  607.  
  608. Customers requiring DTC configurations not provided by the Integrated Cabinet
  609. product can either order a stand-alone DTC48 (2345A) with the appropriate
  610. rack mount kit or select one of the
  611. configurations offered in the Integrated Cabinet product and order additional
  612. DTC Connector cards (X.25 etc.) for installation in the field.
  613.  
  614.  
  615.  
  616. Integrated Cabinet Product Structure
  617. Product Number|| Description
  618. =A1883A       || 1.1m 21U cabinet
  619. =A1884A       || 1.6m 32U cabinet
  620.  
  621. Options
  622.  
  623. =ABA || (A1883A) U.S. 100-120V power
  624. =ABA || (A1884A) U.S. 200-240V power
  625. =ABB || European 200-240V power
  626. =201 || Add 1.3 Gbyte disk
  627. =202 || Add 2.7 Gbyte disk
  628. =203 || Add 4 Gbyte disk
  629. =212 || Add 2.6 Gbyte disk and 2.0 Gbyte DDS
  630. =316 || Add DTC48 with 16 local RS-232 ports
  631. =324 || Add DTC48 with 24 local RS-232 ports
  632. =331 || Add DTC48 with 24 local, 6 remote RS-232 ports
  633. =346 || Add DTC48 with 40 local, 6 remote RS-232 ports
  634. =348 || Add DTC48 with 48 local RS-232 ports
  635.  
  636.  
  637. Use the Factory-Integrated Cabinet selection worksheet on the following page to
  638. choose the cabinet that best meets the customer's needs. Simply fill in the
  639. desired quantities of each component to determine the appropriate cabinet
  640. product for the configuration. Filler panels to cover unused space will be
  641. installed automatically at the factory and do not need to be ordered for the
  642. integrated cabinet products.
  643.  
  644.  
  645.  
  646. Factory Integrated Cabinet Selection Worksheet
  647.  
  648.  
  649. ∅ || Component || Quantity ||  || EIA Units || || Vertical
  650. Space Required (EIA units)
  651. =I. || SPU (select SPU to be racked) %%Option 1CM must be ordered for
  652. factory racking &endash; factory racking recommended.  Factory Integrated
  653. Cabinets have been structured so that all orderable configurations will not
  654. exceed the 16-amp maximum current limit.%%
  655. =∅ =   || a.
  656. 917LX,927LX,937LX,947LX,957LX,967LX
  657. ||  || X || 6 || = || 
  658. =   || b. 937,947,957,967,977,987 ||   || X ||
  659. 10 || = || 
  660. =∅
  661. =II.|| Cabinet options (available on A1883A and A1884A)
  662. =∅ ||A1883A &endash; 1.1 meter cabinet
  663. =∅ ||A1884A &endash; 1.6 meter cabinet
  664. =∅
  665. =   || a. Option 201 - 1.3 Gbyte disk || || X || 4 || = ||
  666.  
  667. =   || b. Option 202 - 2.7 Gbyte disk || || X || 4 || = ||
  668.  
  669. =   || c. Option 203 - 4 Gbyte disk || || X || 4 || = ||
  670.  
  671. =   || d. Option 212 - 2.7 Gbyte disk + DDS ||  || X || 4 || =  ||
  672.  
  673. =   || e. Option 316 - DTC48 with 16 local ports || 
  674.  || X || 6 || = ||
  675. =   || f. Option 324 - DTC48 with 24 local ports ||
  676.  || X || 6 || = ||
  677. =   || g. Option 331 - DTC48 with 24 local, 6 remote ports ||
  678.  || X || 6 || = ||
  679. =   || h. Option 346 - DTC48 with 40 local, 6 remote ports ||
  680.  || X || 6 || = ||
  681. =   || i. Option 348 - DTC48 with 48 local ports ||
  682.  || X || 6 || = ||
  683. =∅
  684. =III. ||Add-on peripherals (not factory-racked and requiring racking kits
  685. &endash; %%see page 2-12 for details%%)
  686. =     ||1. 2345A - DTC48              || || X || 6 || = ||
  687.  
  688. =     ||2. Series 6000 multi-mechanism|| || X || 4 || = ||
  689.  
  690. =     ||3. 7980A/7980XC tape drives    || || X || 5 || = ||
  691.  
  692. =∅
  693. =IV.|| Total EIA units required  (Sum of Total EIA column)
  694. ||  ||  ||  || =  ||
  695. =∅
  696. = V. ||Integrated cabinet selection
  697. If line IV is less than or equal to 21, order cabinet A1883A with appropriate
  698. power, disk, DDS, and DTC48 options.
  699. If line IV is less than or equal to 32, order cabinet A1884A with appropriate
  700. disk, DDS, and DTC48 options.
  701. If line IV is greater than 32, more than one cabinet is required.
  702.  
  703. Cables connecting the SPU and peripherals within the A1883A or A1884A cabinet
  704. are factory-installed and are free of charge.  Cables connecting a cabinet with
  705. another cabinet or separate peripheral must be ordered separately.
  706.  
  707.  
  708. Field-Installed Cabinets
  709.  
  710. Standalone cabinets are also available for customers who decide to rack their
  711. system components after the initial system installation. Care must be
  712. exercised when configuring these cabinets to ensure that all appropriate
  713. cabinet components (filler panels, peripheral mounting kits, etc) are ordered
  714. to successfully rack the system, and that the configuration does not exceed
  715. the 16-amp current limit of the cabinet.  Refer to page 2-11 for a table of
  716. supported racked components. Component racking for these cabinets is performed
  717. at the customer site.
  718.  
  719. For each of the components that need to be racked, the appropriate
  720. racking hardware must be ordered. Order filler panels to cover unused cabinet
  721. space.
  722.  
  723. Rack Mounting Information
  724.  
  725.  
  726. Product Structure
  727. Product/Option || Description
  728. C2785A || 1.1 meter cabinet (21 EIA units)
  729. =ABA         || 100-120V with U.S. power cord
  730. =ABB         || 200-240V with European power cord
  731. =0E3         || Substitute 200-240V for U.S.
  732. =1F9         || Add six 1-unit filler panels
  733. =1FA         || Extractor fan (compatible with cabinet voltage)
  734. =1FC         || Front door (can be locked for security purposes)
  735.  
  736. C2786A || 1.6 meter cabinet (32 EIA units)
  737. =ABA         || 200-240V with U.S. power cord
  738. =ABB         || 200-240V with European power cord
  739. =0E2         || 100-120V with U.S. power cord
  740. =1F9         || Add six 1-unit filler panels
  741. =1FC         || Front door (can be locked for security purposes)
  742.  
  743.  
  744.  
  745. Factory Integrated Cabinet Ordering Examples
  746.  
  747. Product Summary
  748.  
  749. The Series 9x7LX and 9x7 systems share a common product option structure. The
  750. following tables represent information for all of the products and should be
  751. used with the specific configuration rules. They are intended as a general
  752. reference for configuring systems and some caution should be used, because not
  753. all options are available on all systems. Please consult
  754. the HP 3000 Computer Systems Price Guide for the latest product structure.
  755.  
  756.  
  757. Product Structure
  758. Product Number || Description * || Standard\Memory || Standard\Disk
  759. || Standard\User License
  760. =A1770A || Series 917LX  || 24 MB || 670 MB || 1-8
  761. =A1771B || Series 927LX  || 24 MB || 1.3 MB || 1-20
  762. =A1758A || Series 937LX  || 32 MB || 1.3 GB || 1-32
  763. =A1772A || Series 937    || 32 MB || 1.3 GB || 1-32
  764. =A1752B || Series 947LX  || 48 MB || 1.3 GB || 1-100
  765. =A1708B || Series 947    || 64 MB || 1.3 GB || 1-100
  766. =A1707A || Series 957LX  || 64 MB || 1.3 GB || 1-64
  767. =A1709A || Series 957    || 64 MB || 1.3 GB || 1-64
  768. =A1757A || Series 967LX  || 64 MB || 1.3 GB || 1-100
  769. =A1710A || Series 967    || 64 MB || 1.3 GB || 1-100
  770. =A2300A || Series 977    || 96 MB || 1.3 GB || 1-100
  771. =A2317A || Series 987    || 96 MB || 1.3 GB || 1-100
  772.  
  773.  
  774. %%* All preconfigured systems include 2.0 Gbytes DDS format tape drive, MPE/iX
  775. FOS, TurboIMAGE, and ALLBASE/SQL in addition to the standard memory, disk, and
  776. user licenses indicated above.%%
  777.  
  778.  
  779.  
  780.  
  781. Option Structure
  782.  
  783.  
  784. Option Structure\(not all options available on all systems)
  785. Option || Description
  786. = 1B6  ||    Delete 700/92 console
  787. = 1CM  ||    Add cabinet racking hardware (must order with A1883A or A1884A)
  788. = 8Z7  ||    Add floating point coprocessor
  789. = 0E4  ||    Delete battery backup unit
  790. = UCY  ||    40 user license
  791. = UA9  ||    64 user license
  792. = UBD  ||    100 user license
  793. = UCN  ||    160 user license
  794. = UAT  ||    Unrestricted user license
  795. = 007  ||    Increase disk to 1.3 GB
  796. = 009  ||    Increase disk to 2.7 GB
  797. = 011  ||    Increase disk to 4 GB
  798. = 100  ||    Server version
  799. = 401  ||    Add SCSI interface card
  800. = 405  ||    Add PBA-IB (PBA with HP-IB) adapter
  801. = 407  ||    Add PBA-FL (PBA with HP-FL) adapter (PB-FL replaces the PBA-FL)
  802. = 410  ||    Add PB-FL card
  803. = 503  ||    Increase memory to 32 MB
  804. = 504  ||    Increase memory to 40 MB
  805. = 505  ||    Increase memory to 48 MB
  806. = 506  ||    Increase memory to 64 MB
  807. = 508  ||    Increase memory to 96 MB
  808. = 509  ||    Increase memory to 128 MB
  809. = 511  ||    Increase memory to 160 MB
  810. = 513  ||    Increase memory to 192 MB
  811. = 514  ||    Increase memory to 224 MB
  812. = 515  ||    Increase memory to 256 MB
  813. = 517  ||    Increase memory to 320 MB
  814. = 519  ||    Increase memory to 384 MB
  815. = 910  ||    SQL only system (deletes TurboIMAGE)
  816. = 915  ||    TurboIMAGE only system (deletes ALLBASE/SQL)
  817. = 920  ||    MPE/iX only system (deletes TurboIMAGE, SQL)
  818. = 930  ||    Hardware only (deletes TurboIMAGE, SQL, MPE/iX) ICON only
  819.  
  820.  
  821. Upgrade Structure
  822.  
  823.  
  824. Option || Description
  825. = 704  ||    Return MICRO 3000, 3000LX with 2 MB
  826. = 705  ||    Return MICRO 3000GX, RX with 2 MB
  827. = 706  ||    Return MICRO 3000XE
  828. = 707  ||    Return Series II, III, 30, 33, 37, 37XE
  829. = 708  ||    Return HP 250, 260
  830. = 709  ||    Return Series 39, 40, 42, 44, 48
  831. = 710  ||    Return Series 42XP, 52, 58
  832. = 711  ||    Return Series 64, 68 with 2 MB
  833. = 712  ||    Return Series 70 with 2 or 4 MB
  834. = 713  ||    Return Series 920 with 24 MB
  835. = 714  ||    Return Series 925LX with 24 MB
  836. = 715  ||    Return Series 922LX with 24 MB
  837. = 716  ||    Return Series 922RX, 922, 925 with 32 MB
  838. = 717  ||    Return Series 932, 935 with 32 MB
  839. = 718  ||    Return Series 949, 948 with 64 MB
  840. = 719  ||    Return Series 955 with 96 MB
  841. = 720  ||    Return Series 958 with 96 MB, 960 with 128 MB
  842. = 721  ||    Return Series 950 with 64 MB
  843.  
  844.  
  845.  
  846. HP's policy for upgrading HP 3000 systems mandates that systems must be
  847. returned for credit and must have been installed at the customer's site at
  848. least 6 months. Customers must provide documentation of installation date or
  849. proof of support for at least 6 months.
  850.  
  851.  
  852. Field Upgrades
  853.  
  854.  
  855. Field Upgrade Structure
  856. Product || Description
  857. =A1789A   ||  Field Upgrade to Series 927LX
  858. =A1791A   ||  Field Upgrade to Series 937LX
  859. =A1790A   ||  Field upgrade to Series 937
  860. =A1759B   ||  Field Upgrade to Series 947LX
  861. =A1792B   ||  Field Upgrade to Series 947
  862. =A1760A   ||  Field upgrade to Series 957LX
  863. =A1761A   ||  Field Upgrade to Series 957
  864. =A1763A   ||  Field Upgrade to Series 967LX
  865. =A1762A   ||  Field upgrade to Series 967
  866. =A2301A   ||  Field upgrade to Series 977
  867. =A2318A   ||  Field upgrade to Series 987
  868.  
  869. =++Option++
  870. =516  ||    Add 16 MB memory
  871. =532  ||    Add 32 MB memory
  872. =8Z7  ||    Add floating point coprocessor
  873. =UBD  ||    1-100 user license
  874. =UCN  ||    1-160 user license
  875. =UAT  ||    Unrestricted user license
  876. =UCC  ||    Credit for 100 user license on 947LX
  877. =UCD  ||    Credit for unlimited user license on 947LX
  878. =UCE  ||    Credit for 100 user license on 947
  879. =UCF  ||    Credit for unlimited user license on 947
  880. =UCG  ||    Credit for 100 user license on 957LX
  881. =UCH  ||    Credit for unlimited user license on 957LX
  882. =UCJ  ||    Credit for 100 user license on 957
  883. =UCK  ||    Credit for unlimited user license on 957
  884. =UDA  || Credit for 160 user license on 967LX
  885. =UDB  || Credit for unlimited user license on 967LX
  886. =UDC  || Credit for 160 user license on 967
  887. =UDD  || Credit for unlimited user license on 967
  888. =UDL  || Credit for 160 user license on 977
  889. =UDM  || Credit for unlimited user license on 977
  890.  
  891.  
  892.  
  893. Field Upgrade Structure (continued)
  894. Option || Description
  895. =851  ||    From Server 917LX
  896. =852  ||    From Server 927LX
  897. =853  ||    From Server 937LX
  898. =854  ||    From Server 937
  899. =855  ||    From Server 947LX
  900. =856  ||    From Server 947
  901. =857  ||    From Server 957LX
  902. =858  ||    From Server 957
  903. =859  ||    From Server 967LX
  904. =860  ||    From Server 967
  905. =871  ||    From Server 977
  906.  
  907. =861  ||    From Series 917LX
  908. =862  ||    From Series 927LX
  909. =863  ||    From Series 937LX
  910. =864  ||    From Series 937
  911. =865  ||    From Series 947LX
  912. =866  ||    From Series 947
  913. =867  ||    From Series 957LX
  914. =868  ||    From Series 957
  915. =869  ||    From Series 967LX
  916. =870  ||    From Series 967
  917. =872  ||    From Series 977
  918.  
  919.  
  920.  
  921. HP 3000 board and/or chassis upgrades require return of original processor
  922. board and/or chassis to HP. 
  923.  
  924.  
  925.  
  926. Configuration Worksheet
  927.  
  928. The worksheet below will help in configuring a basic multiuser Series 9x7LX or
  929. 9x7 system. Use it as a guideline, but note that particular customer needs
  930. (performance, etc ) may dictate different configuration choices.
  931.  
  932. ++STEP 1 - Select a system++
  933.  
  934. Select the HP 3000 that best fits the customer's performance and user needs.
  935.  
  936.  
  937. System || Standard Memory || Standard Disk || Expansion Slots
  938. =Series 917LX                 ||  24 MB ||   670 MB ||  2
  939. =Series 927LX                 ||  24 MB ||   1.3 GB ||  2
  940. =Series 937LX                 ||  32 MB ||   1.3 GB ||  2
  941. =Series 937                   ||  32 MB ||   1.3 GB || 12
  942. =Series 947LX                 ||  48 MB ||   1.3 GB ||  2
  943. =Series 957LX, 967LX          ||  64 MB ||   1.3 GB ||  2
  944. =Series 947, 957, 967         ||  64 MB ||   1.3 GB || 12
  945. =Series 977                   ||  96 MB ||   1.3 GB || 12
  946. =Series 987                   ||  96 MB ||   1.3 GB || 12
  947.  
  948.  
  949. ++STEP 2 - Determine memory requirements++
  950.  
  951. Memory requirements will vary depending on the specific applications running on
  952. the system. If there is not information available on the memory requirements of
  953. the customer's applications, the following rule of thumb may be used:
  954.  
  955.  
  956. * Memory = 16 Mbytes + (0.5 to 1.0 x number of concurrent users)
  957.  
  958. %%Note 1 MB per user should be used at the low end of the 9x7LX/9x7 family.
  959.  
  960. Note that the maximum supported memory is 192 Mbytes for all 9x7LX systems
  961. and 384 Mbytes for all 9x7 systems.  The 967 has a maximum memory of
  962. 512 Mbytes and the 977 and 987 have a maximum memory of 768 Mbytes at MPE/iX
  963. Release 4.5.%%
  964.  
  965. The following table illustrates the ordering recommendation for the typical
  966. memory configurations.
  967.  
  968.  
  969.  
  970. ∅\SystemMemory (Mbytes)
  971.  
  972. =∅ ||24 || 32 ||40 ||48 ||64 || 96 || 128
  973. || 160 || 192 || 224 || 256 || 320 || 384
  974.  
  975. = 917LX       ||  Std || Opt 503 || Opt 504 ||
  976. = 927LX       ||  Std || Opt 503 || Opt 504 || Opt 505
  977. = 937LX       ||  N/A || Std || Opt 504 || Opt 505|| Opt 506
  978. = 937         ||  N/A || Std || Opt 504 || Opt 505 || Opt 506
  979. = 947LX       ||  N/A || N/A || N/A || Std || Opt 506 || Opt 508
  980. = 947         ||  N/A || N/A || N/A || N/A || Std || Opt 508 || Opt 509 ||
  981. Opt 511 || Opt 513
  982. = 957LX, 967LX ||  N/A || N/A || N/A || N/A || Std || Opt 508 ||
  983. Opt 509 || Opt 511 || Opt 513
  984. = 957 ||  N/A || N/A || N/A || N/A || Std || Opt 508 || Opt 509 || Opt
  985. 511 || Opt 513 || Opt 514
  986. =967 || N/A || N/A || N/A || N/A || Std || Opt 508 || Opt 509 || Opt 511 ||
  987. Opt 513 || Opt 514 || Opt 515
  988. =977  || N/A || N/A || N/A || N/A || N/A || Std || Opt 509 || Opt 511 || Opt
  989. 513 ||  || Opt 515 || Opt 517 || Opt 519
  990. =987 || N/A || N/A || N/A || N/A || N/A || Std || Opt 509 || Opt 511 || Opt 513
  991. ||  || Opt 515 || Opt 517 || Opt 519
  992.  
  993.  
  994. For memory requirements beyond available options, standalone memory must be
  995. ordered: 8 Mbytes (A2230A), 16 Mbytes (A2231A), 32 Mbytes (A2232A), 64 Mbytes
  996. (A2511A), and 128 Mbytes (A2516A) at MPE/iX Release 4.5.  Please be aware of
  997. possible slot limitations due to existing memory modules.
  998.  
  999.  
  1000.  
  1001. ++STEP 3 - Determine disk storage needs++
  1002.  
  1003. Disk requirements will vary with the number of active users and the nature of
  1004. the customer's application. As a general rule of thumb the following formula
  1005. can be used:
  1006.  
  1007.  
  1008. * Disk Storage = 400 Mbytes + (40 Mbytes x Number of Concurrent Users)
  1009.  
  1010.  
  1011. For disk storage beyond what is supported internal to the system package,
  1012. external disks will need to be ordered as stand-alone products.  %%Refer to
  1013. Chapter 6 for more information on external add-on SCSI, HP-FL, and HP-IB disk
  1014. drives.%%
  1015.  
  1016.  
  1017. System || Standard Disk\(SCSI) || Internal Disk Options\(SCSI only)
  1018. || Maximum Disk\ (internal and external)
  1019. = 917LX                             ||  .67 GB || 1.3 GB  ||  24 GB
  1020. = 927LX, 937LX, 947LX, 957LX, 967LX ||  1.3 GB ||  N/A    ||  24 GB
  1021. = 937, 947, 957, 967, 977, 987      ||  1.3 GB || 2.7 GB / 4 GB ||   66 GB
  1022.  
  1023.  
  1024.  
  1025. Enter the number of SCSI disks required (including internal)       
  1026.  
  1027. Enter the number of HP-IB disks required                           
  1028.  
  1029. Enter the number of HP-FL disks required                           
  1030. (Note: LX versions do not support HP-FL)
  1031.  
  1032.  
  1033. ++STEP 4 - Choose a tape backup solution++
  1034.  
  1035. Every Series 9x7LX and 9x7 system comes standard with a 2.0 GB DDS format tape
  1036. drive capable of backing up data at 11 MB/minute. The chart below can be used
  1037. as a guide for selecting an appropriate backup solution. %%See Chapter 6 for
  1038. more detailed information on back-up solutions.%%
  1039.  
  1040.  
  1041. Tape Back-Up Recommendation
  1042.  
  1043. ∅\Type of Back-Up Disk Storage to be
  1044. backed up (Gbytes)
  1045.  
  1046. =∅ || 2.5 || 2.5 - 4 || 4 - 6 || 6 -10 || > 10
  1047.  
  1048. = Unattended (with
  1049.  TurboSTORE/XL II) || 1 DDS || 1 DDS || 1 DDS || 2 DDS
  1050. || ≥ 3 DDS
  1051. = On-line (with
  1052.  TurboSTORE/XL II) || 1 DDS || 1 DDS || 2 DDS || 3 DDS ||
  1053. ≥ 4 DDS
  1054.  
  1055.  
  1056.  
  1057. Enter the number of SCSI DDS drives required (including internal)  
  1058.  
  1059.  
  1060. ++STEP 5 - Select a printer++
  1061.  
  1062. Both system and serial printers are supported on the 9x7LX and 9x7 systems.
  1063. %%Consult chapter 6 for supported printers.%%
  1064.  
  1065.  
  1066. HP-IB system printers require a PBA-IB card (A1747A) which uses two
  1067. HP-PB slots (Series 9x7LX systems have only two slots). Consequently, having an
  1068. HP-IB printer or HP-IB back-up device may require the purchase of a Series 9x7
  1069. package with its expanded number of slots.
  1070.  
  1071.  
  1072.  
  1073. Record the number of HP-IB  printers required                      
  1074.  
  1075. Record the number of serial printers required                      
  1076.  
  1077.  
  1078. ++STEP 6 - Network link products++
  1079.  
  1080. For MPE/iX systems, NS 3000 Point-to-point and IBM (SNA, BSC) communications
  1081. require a
  1082. PSI card. Each PSI card occupies one HP-PB slot.
  1083.  
  1084.  
  1085. Record the number of PSI cards required                            
  1086.  
  1087. Second 802.3 HP-PB LANIC card occupies one HP-PB slot              
  1088.  
  1089. 802.5 Token Ring LAN card occupies one HP-PB slot                  
  1090.  
  1091.  
  1092. ++STEP 7 - I/O interface cards++
  1093.  
  1094. I/O interface cards allow the system to communicate with peripheral devices.
  1095. The number of each card required depends on the number and type of peripheral
  1096. devices that will be connected to the system. Use the configuration rules in
  1097. Chapter 5 to determine the number of SCSI, PBA-IB, and PB-FL interfaces
  1098. required.
  1099.  
  1100. To verify that the number of cards required do not exceed the capacity of the
  1101. system package enter the quantity of each interface card required in the slot
  1102. worksheet below.
  1103.  
  1104.  
  1105. I/O Interface Cards || Quantity || || || || Number of Slots
  1106. = Enter number of SCSI interfaces(not including integrated SCSI on
  1107. MFIO)
  1108. || || X || 1 || = || 
  1109. = ( 9x7LX maximum = 2)
  1110. = ( 9x7 maximum = 10)
  1111. =∅
  1112. = Enter number of PBA-IB interfaces|| || X || 2 || =
  1113. ||
  1114. = ( 9x7LX maximum = 1)
  1115. = ( 9x7 maximum = 2)
  1116. =∅
  1117. = Enter number of PBA-FL interfaces(PBA-FL is obsolete.
  1118. Replace with PB-FL)|| || X || 2 || = ||
  1119. = ( 9x7LX maximum = 0)
  1120. = ( 9x7 maximum = 3)
  1121. =∅
  1122. = Enter number of PB-FL interfaces|| || X || 2 || = ||
  1123.  
  1124. = ( 9x7LX maximum = 1)
  1125. = ( 9x7 maximum = 3)
  1126. =∅
  1127. = Enter number of network link cards (from Step 6)|| || X || 1
  1128. || = || 
  1129. = ( 9x7LX maximum = 2)
  1130. = ( 9x7 maximum = 5)
  1131. = %% Note: If 3 PBA-FL cards selected on 9x7, maximum network link cards = 4.%%
  1132. =∅
  1133. = Total slots required ||  ||  ||  || = || 
  1134. = (9x7LX maximum = 2)
  1135. = (9x7 maximum = 12)
  1136.  
  1137.  
  1138. ++STEP 8 - Terminal connect (DTC16 and DTC48)++
  1139.  
  1140. DTCs are used to connect HP 3000s to local terminals, remote terminals (via
  1141. modems), serial printers, and provide access to X.25 and ARPA networks.  The
  1142. number of DTCs required will depend on the number of ports needed to connect
  1143. users, printers etcetera and the mode of network distribution.
  1144.  
  1145. The table below illustrates the recommended solution for various port
  1146. configurations. %%For further detail on DTC16 or DTC48 or information on X.25
  1147. or Telnet connections, consult Chapter 7.%%
  1148.  
  1149.  
  1150. DTC Recommendations
  1151.  
  1152. ∅ Number of ports required
  1153.  
  1154. =∅ ||   1-32  ||  > than 32
  1155.  
  1156. = 9x7LX or 9x7
  1157. = - Unracked || 2340A   || 2345A
  1158. = - Racked * || A1883A/A1884A|| A1883A/A1884A
  1159.  
  1160.  
  1161. %% * Provides a factory integrated solution with SPU, DTC48, and external disk
  1162. racked in a 1.1 or 1.6 meter cabinet. See pages 2-8 to 2-12 for more
  1163. details on these integrated solutions.%%
  1164.  
  1165.  
  1166. ++STEP 9 - LAN cabling++
  1167.  
  1168. A 2 meter 802.3 LAN cable is included with each Series 9x7LX and 9x7 system
  1169. for attaching the DTC. Distributed DTC configurations will need longer cables
  1170. which are orderable from CPO.
  1171.  
  1172. ++STEP 10 - Console/terminals++
  1173.  
  1174. Each Series 9x7LX and 9x7 system is supplied with one 700/92 terminal as the
  1175. system console. All necessary console attachment hardware is included.
  1176.  
  1177. Several high-quality terminals are available for the HP 3000:
  1178.  
  1179.  
  1180.  
  1181. =Product||Description||Memory||Additional Features
  1182.  
  1183. =700/43 || Multipersonality ASCII || 4 pages || Supports 12 popular
  1184. compatibility modes
  1185. =700/92 || Blockmode VPLUS || 8 pages ||
  1186. =700/94 || High performance blockmode VPLUS || 16 pages || Local forms cache,
  1187. edit checks, modified data tag
  1188. =700/96 || Blockmode VPLUS || 8 pages || High-quality display; EC 92
  1189. regulations (EN 55022B)
  1190. =700/98 ||High performance blockmode VPLUS || 16 pages || High-quality display
  1191. local forms cache, edit checks, modified data tag; EC 92 regulations (EN
  1192. 55022B)
  1193. =700/96ES || Blockmode VPLUS || 8 pages || Compliant with Swedish MPR 1990:10
  1194. guidelines
  1195. =700/98ES ||High performance blockmode VPLUS || 16 pages || Compliant with
  1196. Swedish MPR 1990:10 guidelines
  1197.  
  1198. %%Note:  VPLUS requires a 700/92 or 700/94 terminal.  Oracle's SQL*Forms,
  1199. INGRES forms, and JAM will run on any 700 series terminal.  JAM also runs on a
  1200. block mode terminal, giving the user optimal performance.%%
  1201.  
  1202.  